Back to Stairs

ETHERMA TS – in concrete

Stairway heating for installation in concrete.

  • Soft-elastic to flat-plane laying
  • Easy assembly thanks to custom made mat
  • Only one connection cable
Category:

Description

ETHERMA heating mats are factory-made according to your individual requirements, taking into account the size and number of steps. The number of steps is important because we produce a connected unit which significantly reduces the installation time. The use of the return conductor-heating cables makes the installation easy and simple.

Application

Stairway heating for installation in concrete.

Specification

  • Voltage: 230, 400 V
  • Output: 250 to 350 W/m²
  • Special output: 200 W/m²
  • Nominal limit temperature: up to 105°C
  • Min. temp. of installation: – 5°C
  • Max. perm. bending radius: 5 degrees
  • Outside diameter: 7 mm
  • Protection rating: IP X7
  • Cold lead: 1 x 3 m; 3 x 1.5 (2.5) mm²
  • Approval – heat conductor: CE compliant

Installation

A shallow installation gives a safe and efficient system

There is a proportional relationship between the installation depth of the heating cables, the heating response time and the operating costs. The deeper the heating cables are embedded, the longer the heating time until the defrost surface temperature reaches 3°C. A shallow installation is therefore essential for safety and to ensure lower operating costs.

Heating requirements

Depending on the application: the entire area can be heated which is usually the case in public areas; or for private installations, focused heating is often sufficient to keep a lane free which saves on installation and running costs.

Heating capacity

The required heating capacity per m² of surface area depends on the installation depth, the characteristics of the surface material, and the local climatic conditions.

Intelligent controls

Intelligent open area heating control detects the temperature and humidity of the surface and calculate the heating required, thus ensuring a fully automated, safe and cost-optimized use of the system.

The sensor records the current temperature and the snowfall. In order to switch on the heating, the ambient temperature has drop below the set temperature and the set humidity has to be exceeded. This saves operating costs.

Controls & Accessories

Fully-automatic control system for small areas of <20m² – uses one combined ice and temperature sensor

Fully-automatic control system for small areas of <20m² – includes one combined ice and temperature sensor and sensor housing

Download

PDF media to download etc